Same-Size Batteries: Different Solar Sharer Charging Results?

Same-size batteries may charge differently in Solar Sharer’s three-hour SA window. Compare charging power, available space and realistic evening energy.

Same-Size Batteries: Different Solar Sharer Charging Results?

Same-size batteries may charge differently in Solar Sharer’s three-hour SA window. Compare charging power, available space and realistic evening energy.

Two battery quotes show the same storage capacity. Both mention using Solar Sharer to charge at lunchtime. Would they necessarily put the same amount of energy into storage before 3 pm?

No. Solar Sharer battery charging depends on the installed system’s charging capability, not just its capacity in kWh. Two same-size systems can draw different amounts for charging over the same three-hour window. The energy later delivered to the home must be estimated separately, including losses and reserve settings.

That matters because the battery’s job is to make energy available when your household needs it. A compatible system can store some midday energy for evening cooking, lighting or cooling. The Australian Government includes home-battery charging among uses for Solar Sharer’s free period. When comparing quotes, ask how much the system can actually take in during that opportunity.

In South Australia, the optional offer’s window is 12 pm to 3 pm local time, with up to 24 kWh of eligible grid use in total each day. That allowance belongs to the household, not exclusively to the battery. See the AER’s current rules.

Compare the charging capability, not just the storage number

Capacity in kWh describes how much energy the battery can hold. Charging power in kW describes how quickly energy can go in. The NSW Home Solar Battery Guide (2020), page 26, distinguishes maximum charging and discharging rates.

For this comparison, ask for the grid-charging capability of the complete installed configuration. A battery’s headline rating alone may not describe what its inverter, settings and property supply will permit.

The starting calculation is straightforward: average grid power drawn for battery charging (kW) × time (hours) = charging electricity drawn from the grid (kWh). Here, input means the AC electricity drawn for charging before conversion and storage losses, excluding other household loads. A maximum rating is not automatically the average maintained for all three hours, and a DC battery-side rating should not be substituted without accounting for conversion.

The same capacity, but different three-hour results

Worked illustration, not measured product performance. The 20 kWh capacity, 3 kW and 5 kW average inputs, and 6 kWh of household use are hypothetical teaching values, not product specifications or household averages. Assume both systems have 20 kWh of usable capacity and 20 kWh of available space at noon. There is no rooftop-solar input or battery discharge during the window. Each proposed installation is assumed capable of its stated average AC grid-charging input across the full three hours while supplying other household loads. Other household grid use totals 6 kWh. These conditions must be verified before using this calculation in a real proposal.

The household therefore has 18 kWh left within the free allowance for charging. Now change just the average grid-charging input:

Hypothetical comparison itemSystem ASystem B
Usable storage capacity20 kWh20 kWh
Available space at noon20 kWh20 kWh
Assumed average grid-charging input3 kW5 kW
Electricity drawn for charging over three hours3 × 3 = 9 kWh5 × 3 = 15 kWh

Both have the same storage space and both stay within the assumed remaining allowance. Yet System B draws 6 kWh more for charging because its average charging input is higher. The capacity figure alone would hide that difference.

These figures are charging input, before allowing for storage and conversion losses. They are not a promise of 9 or 15 kWh delivered to appliances, or of a particular bill saving. The government battery guide explains that charging and discharging involve energy losses.

If only System A’s storage capacity increased, while its charging input stayed at 3 kW, the same three-hour calculation would still be 9 kWh. More space alone does not make that charging path faster.

When charging speed is not the limiting factor

A higher charging rate only helps while there is room and a source of energy available. In a separate hypothetical situation, suppose the battery has just 4 kWh of space left at noon because it charged from morning solar. That is additional storage space, not the grid input needed to fill it: charging losses also matter. The original nine- and fifteen-kWh input calculations cannot simply be reused once available space limits charging.

Energy already stored still has value. It should simply be counted separately from new midday charging. With rooftop solar contributing, the forecast also needs to separate solar input from grid input: your own generation is not imported electricity under the retailer’s allowance.

Similarly, household grid use shares the 24 kWh allowance. Exceeding it attracts the offer’s excess-use charge. Faster charging is not permission to assume unlimited zero-cost input. The AER explains the total allowance and excess-use treatment.

Ask for one comparable charging estimate in both quotes

Give each proposed system the same starting conditions: battery charge level at noon, household use during the window, available solar and intended tariff. Then ask for:

  • The expected average grid-charging input for that installation, and what limits it.
  • The resulting three-hour charging input, with solar contribution shown separately.
  • The energy expected to be available to the household later, after losses and reserve settings.

This makes the comparison about usable evening support rather than matching capacity labels. If a quote relies on uninterrupted charging at a maximum rate, ask whether that assumption is realistic for your property.

Charging performance is only one part of the purchase decision. For tariff costs, supply charges and the broader switching comparison, use our existing Solar Sharer whole-bill guide. A faster-charging system is not automatically the better-value purchase.

Frequently asked questions

1. Do batteries with the same kWh capacity charge at the same speed?

Not necessarily. Capacity describes storage space; charging capability depends on the proposed equipment and installed configuration. Request the charging input used in the forecast, not just the capacity.

2. Can I use the power-output figure to calculate grid charging?

Do not assume so. Output describes discharge to the home. Ask for the relevant charging rating and installed grid-charging limit; charging and discharging specifications are distinct.

3. Will extra battery modules always capture more in the free window?

No. They may add capacity, but additional three-hour intake also requires available space, charging capability and an energy source. Check what changes in the actual configuration rather than assuming more modules mean faster charging.

4. Can I multiply the maximum charging rating by three?

That is a theoretical starting point only if the rate can be sustained for the full window. A practical forecast should use expected charging behaviour, including any interruptions or reduction as the battery fills.

5. Does faster charging mean guaranteed lower bills?

No. The benefit depends on how much additional energy is genuinely stored and used later, the tariff, losses and installed cost. Drawing more charging electricity does not by itself establish more usable output or greater savings. Compare the evening contribution and total costs, not charging speed alone.

Compare what the battery can do for your home

The useful question is not just “How much can this battery hold?” It is “How much can this system charge during the available window, and leave for our evening?”

Explore SunEnergy’s home battery solutions in Adelaide. Bring your recent bill, existing solar details and any battery quotes. Ask for a comparison of the proposed charging capability and realistic evening contribution, alongside the installed price.

Sources

Keep reading

Social Media Posts

Check out our latest social media posts